Your trusted compressed air filtration expert
30 Years Dedicated to Compressed Air Filtration & Separation Technology. Serving Petrochemical, Power, Cement, Plastic, Laser Cutting & More
Home / All / Centrifugal Strainer / Vacuum Pre-Filter for Vacuum Pumps
Vacuum Pre-Filter for Vacuum Pumps
Vacuum Pre-Filter for Vacuum PumpsVacuum Pre-Filter for Vacuum PumpsVacuum Pre-Filter for Vacuum PumpsVacuum Pre-Filter for Vacuum Pumps

Vacuum Pre-Filter for Vacuum Pumps

Share
CategoriesCentrifugal Strainer
BrandAIRPULL
Flow capacity885-8,415 m3/h
ConnectionDN80-DN300 flanged
Filtration99% at 2 um
Temperature-26 to 104 C
Flange standardHG/T 20592
Pressure test0.5 bar positive
FOB portshanghai
Terms of PaymentL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal
Detail Information
Vacuum inlet filtration

Vacuum Pre-Filter

Protect the pump rotor before dust and liquid ever reach it.

Installed at the inlet of a vacuum pump, this pre-filter removes solid dust and small amounts of entrained liquid from the process gas, keeping the moving parts of the pump free from wear and corrosion.

DN80 - DN300 flanges 885 - 8,415 m³/h Polyester or paper media
885 - 8,415Flow rate range (m³/h)
DN80 - DN300Flange inlet / outlet
99% @ 2 µmPaper element efficiency
-26 to 104 °COperating temperature
Product overview / 01

Clean gas in. Longer pump life out.

The vacuum pre-filter is mounted at the front of the vacuum pump inlet. It filters dust and a small amount of liquid carried in the gas, protecting the pump rotor against damage.

While the pump is running, solid dust is intercepted on the surface of the filter media. A small amount of liquid is filtered out, coalesces and sinks to the bottom of the housing, then leaves through the liquid discharge line. Clean gas continues into the vacuum pump, preventing wear and corrosion of the moving pair.

The result is a stable suction line, less contamination inside the pump and a longer service life for the equipment downstream.

Rotor protection

Dust and entrained liquid are stopped before they can reach the pump's moving parts.

Liquid separation and drain

Coalesced liquid collects at the bottom of the housing and is discharged through the drain line.

Extended service intervals

Clean gas entering the pump helps safeguard its service life and reduces unplanned maintenance.

Working principle / 02

How the filter works

The filter operates in a negative pressure state. As dust-laden gas passes through the media, coarse and fine particles are separated in two different ways.

01

Negative-pressure operation

The unit is installed on the suction side and works under vacuum conditions, with a sealed housing that holds pressure without leakage.

02

Gravity settling of coarse particles

When the dust-containing gas passes through the filter material, larger particles are filtered to the bottom of the container under gravity.

03

Fine particle capture

Small particles are adsorbed onto the surface of the fibre through Brownian movement and diffusion, so clean gas enters the vacuum pump and its service life is maintained.

Product characteristics / 03

Engineered for the suction line

Operating limits, sealing performance and filter media efficiency as specified in the AIRPULL catalogue.

01 / TEMPERATURE

Wide operating range

Operating temperature -26 °C to 104 °C, covering both cold-start and warm process conditions.

02 / ENVIRONMENT

Vacuum service

Designed for use under vacuum above -100 kPa, on the inlet side of the pump.

03 / SEALING

Leak-free sealing

Positive pressure test at 0.5 bar with no leakage during the pressure hold.

04 / MEDIA

Filter element accuracy

Polyester 99% @ 5 µm and paper 99% @ 2 µm elements are available.

Selection & applications / 04

Configured for your pump

Housing material, installation orientation and connections can be matched to the vacuum equipment and process conditions.

Type selection

Options listed in the AIRPULL catalogue.

Material

Stainless steel or epoxy treatment, etc.

Installation mode

Vertical or horizontal

Interface

Supports customization

Specifications

Dimensions

Flange Inlet / OutletFlow Rate m³/hA / mmB / mmH0 / mmH1 / mm
DN80885356299689470
DN80885356299689470
DN100885356299689470
DN100885356299689470
DN1251360470279714495
DN1251360470279724495
DN1501870470305704521
DN1501870470305704521
DN2003060572356965648
DN25049306864101130864
DN30079906864101130864
DN250493067240614611143
DN300841567240614611143
DN300841567240617651448
Vacuum pre-filter dimension drawing

Request a quote

Send your flow rate, connection size and service conditions and our team will configure the right vacuum pre-filter for your pump.

Request a quote

© 2026 AIRPULL. Technical data from the AIRPULL vacuum pre-filter catalogue.

Review
  • 加载中···

Please send your message to us

*Email
Phone
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
30 Years Dedicated to Compressed Air Filtration & Separation Technology. Serving Petrochemical, Power, Cement, Plastic, Laser Cutting & More
Contact Person
Jeff Zhang
Full Name:
Jeff Zhang
Tel:

+86 19836212010

Email:
sales@airpulltech.com
WhatsApp:
8619836212010
Address:
No. 1506, Xinqi Street, National Chemical and Physical Power Sources Industrial Park, Muye District, Xinxiang City, Henan Province (1000 meters north of the intersection of Beihuan Road and Xinqi Stre

Please send your message to us

*Email
Phone
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Your trusted compressed air filtration expert